GE LM6000 series units

One of the world’s most widely installed aeroderivative gas turbines: a two-shaft model derived from GE’s CF6‑80C2 high-bypass-ratio aircraft engine, offering aviation‑grade power density, rapid start-up, and excellent part‑load efficiency—making it a leading choice for data center primary power and peaking applications.

≈ 43 MW · PA (ISO),≈ 40% efficiency (LHV),Two-shaft aero‑derivative,Natural Gas / Dual-Fuel,50 / 60 Hz

Platform Parameters

Typical Technical Parameters (ISO Conditions)

The table below lists representative platforms and typical parameters (under ISO operating conditions). For the specific units currently for sale, we can provide the serial numbers, operating hours, test reports, and commercial terms; a complete equipment list will be made available upon signing a confidentiality agreement.

Parameter Value / Description
ISO power ISO output ≈ 43 MW (PA type, single unit); PB/PF types up to approximately 50 MW class
Lower Heating Value (LHV) ≈ 40%
Total pressure ratio ≈ 29 : 1
Structure Two spools: a 5-stage variable-geometry low-pressure compressor, a 14-stage high-pressure compressor, an annular combustor, and high- and low-pressure (power) turbines.
Prototype aircraft GE CF6-80C2
Fuel Natural gas (dual-fuel configuration available)
Frequency and Grid Connection 50/60 Hz; Example configuration: a 11 kV synchronous generator coupled to a 3,000 rpm drive via a 1.209:1 reduction gear. 50/60 Hz;
Typical Delivery Spot‑order lead time is approximately 2–4 months (subject to commercial confirmation).

Scope of Supply

Main equipment, auxiliary equipment, and a complete set of documents

Generator and Transmission Chain

Gas turbine core, reduction gear, generator, lubricating oil and fuel gas systems, exhaust stack, sound enclosure, and instrumentation and control.

Waste Heat and Steam Cycle (as per original manufacturer’s configuration)

The waste heat boiler, steam turbine, and steam–water system can be supplied as a complete package, supporting the reconstruction of combined-cycle power plants.

Electrical, Control, and Safety

Control systems (such as Woodward MicroNet Plus), NOx control, transformers and switchgear, fire protection systems, and electrical accessories.

Random Document

OEM manuals and drawings, test reports, maintenance records, operating hour logs, and borescope inspection reports are delivered together with the equipment.